RECTY |
Record type for batch input of task lists |
CHAR |
2 |
0 |
|
RECTY
|
|
PLNTY |
Task List Type |
CHAR |
1 |
0 |
*
|
PLNTY
|
|
PLNNR |
Key for Task List Group |
CHAR |
8 |
0 |
|
PLNNR
|
|
PLNAL |
Group Counter |
CHAR |
2 |
0 |
|
PLNAL
|
|
PLNFL |
Sequence |
CHAR |
6 |
0 |
|
PLNFOLGE
|
|
VORNR |
Operation/Activity Number |
CHAR |
4 |
0 |
|
VORNR
|
|
MERKNR |
Inspection Characteristic Number (Batch Input) |
CHAR |
4 |
0 |
|
QMERKNR_C
|
|
KURZTEXT |
Short Text |
CHAR |
40 |
0 |
|
QKURZTEXT
|
|
TXTSP |
Language key (batch input) |
CHAR |
1 |
0 |
|
SPRAS_BI
|
|
VSTEUERKZ |
Key Containing Preset Characteristic Control Indicators |
CHAR |
4 |
0 |
*
|
QSTEUERKZ
|
|
TOLERANZSL |
Tolerance Key |
CHAR |
4 |
0 |
*
|
QTOLERANZ
|
|
QUANTITAT |
Quantitative Characteristic |
CHAR |
1 |
0 |
|
QKZQUNMK
|
|
MESSWERTE |
Measured Values Must Be Recorded |
CHAR |
1 |
0 |
|
QKZQUMK
|
|
PRUEFKAT |
Reference to Characteristic Attribute Required |
CHAR |
1 |
0 |
|
QKZPKAT
|
|
TOLEROBEN |
Upper Specification Limit |
CHAR |
1 |
0 |
|
QKZTOLOB
|
|
TOLERUNTEN |
Lower Specification Limit |
CHAR |
1 |
0 |
|
QKZTOLUN
|
|
SOLLPRUEF |
Check Target Value |
CHAR |
1 |
0 |
|
QKZSOLLPR
|
|
PUMFKZ |
Inspection Scope |
CHAR |
1 |
0 |
|
QPUMFKZ
|
|
Scope Not Fixed |
< |
Smaller Inspection Scope Allowed |
= |
Fixed Inspection Scope |
> |
Larger Inspection Scope Allowed |
|
LZEITKZ |
Long-Term Inspection |
CHAR |
1 |
0 |
|
QLZEITKZ
|
|
ESTUKZ |
Recording Type |
CHAR |
1 |
0 |
|
QESTUKZ
|
|
Summarized Recording |
* |
Classed Recording |
+ |
Single-Value Recording |
- |
No Results Recording |
|
DOKUKZ |
Documentation Required for Inspection Results |
CHAR |
1 |
0 |
|
QDOKUKZ
|
|
Text Documentation of Test Values Is Not Required |
+ |
All Test Values Must Be Documented with Text |
. |
Test Values with Valuation R (Reject) Must Be Documented |
|
RZWANG |
Characteristic Category |
CHAR |
1 |
0 |
|
QRZWANG
|
|
Optional Characteristic |
+ |
Required When Previous Required Characteristic Is Accepted |
- |
Required When Previous Required Characteristic Is Rejected |
X |
Required Characteristic |
|
SYNCRO |
Synchronization is Active |
CHAR |
1 |
0 |
|
QSYNCRO
|
|
ADDPRO |
Inspection Sample Quantity Is Added |
CHAR |
1 |
0 |
|
QADDPRO
|
|
ZERSTPRF |
Destructive Inspection |
CHAR |
1 |
0 |
|
QKZDESTROY
|
|
FORMELMK |
Calculated Characteristic |
CHAR |
1 |
0 |
|
QKZFORMEL
|
|
No Formula |
1 |
Input Processing |
X |
Calculated Characteristic |
|
STICHPR |
Sampling Procedure Is Required |
CHAR |
1 |
0 |
|
QSTICHPR
|
|
AUSSLOS |
Characteristic Relevant for Quality Score and Scrap Share |
CHAR |
1 |
0 |
|
QAUSSLOS
|
|
FIXIERT |
Default Control Indicators Cannot Be Changed |
CHAR |
1 |
0 |
|
QNAENDKZ
|
|
BEWFHLZHL |
Recording the Number of Defects |
CHAR |
1 |
0 |
|
QBFHLZHL
|
|
LSTKZ |
Control Characteristics Results - QM Subsystem |
CHAR |
1 |
0 |
|
QLEITSTKZ
|
|
VORGAEND |
Specifications Can Be Changed |
CHAR |
1 |
0 |
|
QVORGAEND
|
|
PMMZWANG |
Assignment of Test Equipment Required |
CHAR |
1 |
0 |
|
QPMZWANG
|
|
FEHLREC |
Defects Recording Automatically Called Up |
CHAR |
1 |
0 |
|
QFEHLREC
|
|
AENDBELEG |
Create Change Documents During Results Recording |
CHAR |
1 |
0 |
|
QKZAENBEL
|
|
QSPCMK |
SPC Characteristic |
CHAR |
1 |
0 |
|
QSPCMK
|
|
KEINDRUCK |
Print |
CHAR |
1 |
0 |
|
QDRUCK1
|
|
Print |
* |
Do Not Print at Skip |
X |
Do Not Print |
|
PARA |
Control Indicator "Parameter Characteristic" Set/Not Set |
CHAR |
1 |
0 |
|
QPARA
|
|
PROCESSMK |
Process Characteristic |
CHAR |
1 |
0 |
|
QKZPROCCHAR
|
|
VERWMERKM |
Master Inspection Characteristic |
CHAR |
8 |
0 |
*
|
QMERKNR
|
|
QPMK_REF |
Reference to Master Insp. Characteristic in Task List |
CHAR |
1 |
0 |
|
QKZ_REF
|
|
QPMK_ZAEHL |
Plant for the Master Inspection Characteristic |
CHAR |
4 |
0 |
|
QZAEHLER
|
|
MKVERSION |
Version Number of Master Inspection Characteristic |
CHAR |
6 |
0 |
|
QVERSNRMK
|
|
PMETHODE |
Inspection Method |
CHAR |
8 |
0 |
*
|
QPMETHODE
|
|
QMTB_WERKS |
Plant |
CHAR |
4 |
0 |
*
|
WERKS_D
|
|
PMTVERSION |
Version Number of Inspection Method |
CHAR |
6 |
0 |
|
QVERSNRPM
|
|
PROBENR |
Partial Sample for an Insp. Characteristic (Batch Input) |
CHAR |
3 |
0 |
|
QPROBEPL_C
|
|
PRUEFQUALI |
Inspector Qualification |
CHAR |
5 |
0 |
*
|
QPRQUALIF
|
|
MERKGEW |
Weighting of Characteristic |
CHAR |
2 |
0 |
*
|
QMERKGEW
|
|
EEANTVERF |
Fraction Calculation |
CHAR |
2 |
0 |
*
|
QEANTVERF
|
|
PSNFH |
Item number of the production resource/tool (batch input) |
CHAR |
4 |
0 |
|
PSNFH_BI
|
|
DUMMY10 |
Text Line for Additional Information |
CHAR |
10 |
0 |
|
QTXT10
|
|
DUMMY20 |
Text Line for Additional Information |
CHAR |
20 |
0 |
|
QTXT20
|
|
DUMMY40 |
Text Line for Additional Information |
CHAR |
40 |
0 |
|
QTXT40
|
|
STICHPRVER |
Sampling Procedure in Inspection Characteristic |
CHAR |
8 |
0 |
*
|
QSTICHVERF
|
|
PROBEMGEH |
Sample Unit of Measure (Batch Input) |
CHAR |
3 |
0 |
|
QPROBME_C
|
|
PRUEFEINH |
Sample Quantity Factor for Sample (Batch Input) |
CHAR |
6 |
0 |
|
QPROBEFAKC
|
|
SPCKRIT |
SPC Criterion |
CHAR |
3 |
0 |
*
|
QSPCKRIT
|
|
DYNMERKREF |
Tlist Characteristic, Whose Q-Level Is Copied (Batch Input) |
CHAR |
4 |
0 |
|
QMERKDYN_C
|
|
QDYNREGEL |
Dynamic Modification Rule |
CHAR |
3 |
0 |
*
|
QDYNREGEL
|
|
LIEFKZ |
Supplier Considered for Dynamic Modification |
CHAR |
1 |
0 |
|
QLIFKZ
|
|
HERSTKZ |
Manufacturer Considered for Dynamic Modification |
CHAR |
1 |
0 |
|
QHERSTKZ
|
|
KUNDKZ |
Customer Considered for Dynamic Modification |
CHAR |
1 |
0 |
|
QKUNDKZ
|
|
STELLEN |
No. of Decimal Places (Batch Input) |
CHAR |
2 |
0 |
|
QSTELLEN_C
|
|
MASSEINHSW |
Measurement Unit in Which Quantitative Data Is Maintained |
CHAR |
6 |
0 |
*
|
QMGEH6
|
|
SOLLWERT |
Target Value for a Quantitative Characteristic |
CHAR |
16 |
0 |
|
QSOLLWERTC
|
|
TOLERANZOB |
Upper Specification Limit |
CHAR |
16 |
0 |
|
QTOLOBC
|
|
TOLERANZUN |
Lower Specification Limit |
CHAR |
16 |
0 |
|
QTOLUNC
|
|
KLASANZAHL |
Number of Value Classes for Inspection Results |
CHAR |
3 |
0 |
|
QKLASSZAHC
|
|
KLASBREITE |
Class Width |
CHAR |
16 |
0 |
|
QKLASSBRC
|
|
KLASMITTE |
Class Midpoint |
CHAR |
16 |
0 |
|
QKLASMITC
|
|
GRENZEOB1 |
First Upper Specification Limit |
CHAR |
16 |
0 |
|
QGRENZO1C
|
|
GRENZEUN1 |
First Lower Specification Limit |
CHAR |
16 |
0 |
|
QGRENZU1C
|
|
GRENZEOB2 |
Second Upper Specification Limit |
CHAR |
16 |
0 |
|
QGRENZO2C
|
|
GRENZEUN2 |
Second Lower Specification Limit |
CHAR |
16 |
0 |
|
QGRENZU2C
|
|
PLAUSIOBEN |
Upper Plausibility Limit |
CHAR |
16 |
0 |
|
QPLAUSIOBC
|
|
PLAUSIUNTE |
Lower Plausibility Limit |
CHAR |
16 |
0 |
|
QPLAUSIUNC
|
|
TOLERWEIOB |
Change to Upper Specification Limit |
CHAR |
16 |
0 |
|
QTOLWOBC
|
|
TOLERWEIUN |
Change to Lower Specification Limit |
CHAR |
16 |
0 |
|
QTOLWUNC
|
|
TOLERWAB |
Date, from Which the Tolerance Change Is Valid (Batch Input) |
CHAR |
10 |
0 |
|
QTOLWAB_C
|
|
TOLERWBIS |
Date, to Which the Tolerance Change Is Valid (Batch Input) |
CHAR |
10 |
0 |
|
QTOLWBIS_C
|
|
FORMELSL |
Check and Calculate Formula in QM |
CHAR |
1 |
0 |
|
QFORMELSL
|
|
FORMEL1 |
Formula Field |
CHAR |
60 |
0 |
|
QFORMEL
|
|
FORMEL2 |
Formula Field |
CHAR |
60 |
0 |
|
QFORMEL
|
|
CODEGRQUAL |
Defect Code Group for General Rejection |
CHAR |
8 |
0 |
*
|
QCODEGRPQL
|
|
CODEQUAL |
Defect Code for Rejection: General |
CHAR |
4 |
0 |
*
|
QCODEQL
|
|
CODEGR9U |
Defect Code Group for Rejection at Lower Tolerance |
CHAR |
8 |
0 |
*
|
QCODEGRPU
|
|
CODE9U |
Defect Code for Rejection at Lower Specification Limit |
CHAR |
4 |
0 |
*
|
QCODEU
|
|
CODEGR9O |
Defect Code Group for Rejection at Upper Tolerance |
CHAR |
8 |
0 |
*
|
QCODEGRPO
|
|
CODE9O |
Defect Code for Rejection at Upper Specification Limit |
CHAR |
4 |
0 |
*
|
QCODEO
|
|
KATAB1 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART1 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
*
|
QKATAUSW
|
|
AUSWMENGE1 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
AUSWMGWRK1 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
*
|
QWERKAUSW
|
|
KATAB2 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART2 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
*
|
QKATAUSW
|
|
AUSWMENGE2 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
AUSWMGWRK2 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
*
|
QWERKAUSW
|
|
KATAB3 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART3 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
*
|
QKATAUSW
|
|
AUSWMENGE3 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
AUSWMGWRK3 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
*
|
QWERKAUSW
|
|
KATAB4 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART4 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
*
|
QKATAUSW
|
|
AUSWMENGE4 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
AUSWMGWRK4 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
*
|
QWERKAUSW
|
|
KATAB5 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART5 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
*
|
QKATAUSW
|
|
AUSWMENGE5 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
AUSWMGWRK5 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
*
|
QWERKAUSW
|
|
INPPROC |
Parameters for Input Processing in QM Results Recording |
CHAR |
3 |
0 |
|
QINPPROC
|
|