SATZART |
Record Types for QM Interface - Subsystems |
CHAR |
3 |
0 |
|
QEIFART
|
Q40 |
Inspection lot requirements |
Q41 |
Req. for insp. lot header record |
Q42 |
Char. specifications for subsystem |
Q45 |
Download inspection catalog entries |
Q48 |
Status changes in insp. lot |
Q51 |
Quantative original value record for single unit |
Q52 |
Qualitative orig. value rec. for sing. unit with char. code |
Q53 |
Qualitative orig. value rec. for sing. unit with valuation_ |
Q54 |
Quantative original value record for inspection point_ |
Q55 |
Qualitative orig. value rec. with char. code for insp. point |
Q56 |
Qualitative orig. value rec. with valuation for insp. point |
Q58 |
Cancel single unit record |
Q61 |
Quantative sample record |
Q62 |
Qualitative sample record with characteristic code |
Q63 |
Qualitative sample record with valuation |
Q64 |
Quantative sample record for inspection point |
Q65 |
Qualitative sample record with char. code for insp. point |
Q66 |
Qualitative sample rec. with valuation for insp. point |
Q68 |
Cancel sample record |
Q69 |
Close sample record |
Q71 |
Quantitative characteristic record |
Q72 |
Qualitative characteristic set with char. code |
Q73 |
Qualitative characteristic set with valuation |
Q79 |
Close character. |
Q83 |
Confirmation for inspection point |
Q84 |
Valuation for inspection point |
Q88 |
Usage Decision for Inspection Lot |
Q89 |
Inspection cancelled for inspection lot |
Q90 |
Insp.lot defects |
Q91 |
Operation defects |
Q92 |
Characteristic / sample defects |
Q95 |
Operation defects with reference to an inspection point |
Q96 |
Characteristic defects with reference to an inspection point |
|
RUECKMELNR |
Confirmation Number for Inspection Characteristic |
NUMC |
8 |
0 |
|
QRUECKNR
|
|
ERFASSART |
Recording Type for Inspection Characteristic |
CHAR |
1 |
0 |
|
QEIFERFAS
|
A |
Measured values for single unit |
B |
Code for single unit |
C |
Valuation for single unit (O.K./n.O.K.) |
D |
Measured values for sample |
E |
Code for sample |
F |
Valuation of a sample |
G |
Measured value for characteristic |
H |
Code for characteristic |
I |
Valuation of a characteristic |
J |
Measured values for single unit in a sample |
K |
Code for single unit in a sample |
L |
Valuation for single unit in a sample |
M |
Measured values for single unit in an insp. pt.-based sample |
N |
Code for single unit in an inspection point-based sample |
O |
Valuation for single unit in inspection point-based sample |
P |
Measured values for sample for an inspection point |
Q |
Code for sample for an inspection point |
R |
Valuation for the sample for an inspection point |
|
KZBEWSUBSY |
Valuate Inspection Characteristic on Subsystem |
CHAR |
1 |
0 |
|
QEIFBEWSUB
|
|
BEWART |
Valuation Type for Characteristic for QM Subsystems |
CHAR |
1 |
0 |
|
QEIFBEWMK
|
|
KZRZWANG |
Required Confirmation for Inspection Characteristic |
CHAR |
1 |
0 |
|
QEIFRWANG
|
|
STATUSV |
Specification Record Status |
CHAR |
1 |
0 |
*
|
QSTATUS
|
|
STATUSR |
Results Record Status |
CHAR |
1 |
0 |
*
|
QBEASTATUS
|
|
KZPRUMF |
Inspection Scope |
CHAR |
1 |
0 |
|
QPUMFKZ
|
|
Scope Not Fixed |
< |
Smaller Inspection Scope Allowed |
= |
Fixed Inspection Scope |
> |
Larger Inspection Scope Allowed |
|
KZDOKU |
Documentation Required for Inspection Results |
CHAR |
1 |
0 |
|
QDOKUKZ
|
|
Text Documentation of Test Values Is Not Required |
+ |
All Test Values Must Be Documented with Text |
. |
Test Values with Valuation R (Reject) Must Be Documented |
|
KZSERNR |
Serial Number To Be Recorded in QM Subsystem |
CHAR |
1 |
0 |
|
QEIFSERNR
|
|
KZTSTICHPR |
Partial Samples Possible |
CHAR |
1 |
0 |
|
QTSTICHPRO
|
|
KZRAST |
Sampling Procedure for Inspection Points |
CHAR |
1 |
0 |
|
QKZRAST
|
|
Without Inspection Points |
1 |
Inspection Points for Plant Maintenance |
2 |
Inspection Points for Sample Management |
X |
Inspection Points for Production |
|
RASTER |
Inspection Frequency (Only for Inspection with Insp. Points) |
NUMC |
3 |
0 |
|
QRASTER
|
|
SOLLSTPANZ |
Number of Planned Partial Samples |
CHAR |
5 |
0 |
|
QEIFSTPANZ
|
|
BEWARTSP |
Valuation Type for Sample for QM Subsystems |
CHAR |
1 |
0 |
|
QEIFBEWSP
|
|
PRUEFLOS |
Inspection Lot Number |
NUMC |
12 |
0 |
QALS
|
QPLOS
|
|
PLNFL |
Sequence |
CHAR |
6 |
0 |
|
PLNFOLGE
|
|
VORNR |
Operation/Activity Number |
CHAR |
4 |
0 |
|
VORNR
|
|
MERKNR |
Inspection Characteristic Number |
NUMC |
4 |
0 |
|
QMERKNRP
|
|
QPMK_WERKS |
Plant for Master Inspection Characteristic |
CHAR |
4 |
0 |
|
QEIFPMKWRK
|
|
VERWMERKM |
Master Inspection Characteristic |
CHAR |
8 |
0 |
QPMK
|
QMERKNR
|
|
MKVERSION |
Version Number of Master Inspection Characteristic |
CHAR |
6 |
0 |
|
QVERSNRMK
|
|
QMTB_WERKS |
Plant for Inspection Method |
CHAR |
4 |
0 |
T001W
|
QEIFMTBWRK
|
|
PMETHODE |
Inspection Method |
CHAR |
8 |
0 |
QMTB
|
QPMETHODE
|
|
PMTVERSION |
Version Number of Inspection Method |
CHAR |
6 |
0 |
|
QVERSNRPM
|
|
PMTKURZTXT |
Short Text for Inspection Method |
CHAR |
40 |
0 |
|
QEIFPMTTXT
|
|
PRUEFQUALI |
Inspector Qualification |
CHAR |
5 |
0 |
*
|
QPRQUALIF
|
|
MERKGEW |
Weighting of Characteristic |
CHAR |
2 |
0 |
TQ17A
|
QMERKGEW
|
|
GEWKURZTXT |
Short Text for Characteristic Weighting |
CHAR |
40 |
0 |
|
QEIFGEWTXT
|
|
KURZTEXT |
Short Text for the Inspection Characteristic |
CHAR |
40 |
0 |
|
QMKKURZTXT
|
|
FORMEL |
Complete Formula for Linking Insp. Char. to QM Subsystems |
CHAR |
120 |
0 |
|
QEIFFORMEL
|
|
DUMMY10 |
Text Line for Additional Information |
CHAR |
10 |
0 |
|
QTXT10
|
|
DUMMY20 |
Text Line for Additional Information |
CHAR |
20 |
0 |
|
QTXT20
|
|
DUMMY40 |
Text Line for Additional Information |
CHAR |
40 |
0 |
|
QTXT40
|
|
STELLEN |
Number of Decimal Places |
NUMC |
2 |
0 |
|
QEIFSTELLE
|
|
MASSEINHSW |
Unit of Measurement for the Inspection Characteristic |
UNIT |
3 |
0 |
T006
|
QEIFPRFMK
|
|
SOLLWERT |
Target Value for a Quantitative Characteristic |
CHAR |
16 |
0 |
|
QSOLLWERTC
|
|
TOLERANZOB |
Upper Specification Limit |
CHAR |
16 |
0 |
|
QTOLOBC
|
|
TOLERANZUN |
Lower Specification Limit |
CHAR |
16 |
0 |
|
QTOLUNC
|
|
PLAUSIOBEN |
Upper Plausibility Limit |
CHAR |
16 |
0 |
|
QPLAUSIOBC
|
|
PLAUSIUNTE |
Lower Plausibility Limit |
CHAR |
16 |
0 |
|
QPLAUSIUNC
|
|
GRENZEOB1 |
First Upper Specification Limit |
CHAR |
16 |
0 |
|
QGRENZO1C
|
|
GRENZEUN1 |
First Lower Specification Limit |
CHAR |
16 |
0 |
|
QGRENZU1C
|
|
GRENZEOB2 |
Second Upper Specification Limit |
CHAR |
16 |
0 |
|
QGRENZO2C
|
|
GRENZEUN2 |
Second Lower Specification Limit |
CHAR |
16 |
0 |
|
QGRENZU2C
|
|
KATAB1 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART1 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
TQ15
|
QKATAUSW
|
|
AUSWMGWRK1 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
T001W
|
QWERKAUSW
|
|
AUSWMENGE1 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
KATAB2 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART2 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
TQ15
|
QKATAUSW
|
|
AUSWMGWRK2 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
T001W
|
QWERKAUSW
|
|
AUSWMENGE2 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
KATAB3 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART3 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
TQ15
|
QKATAUSW
|
|
AUSWMGWRK3 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
T001W
|
QWERKAUSW
|
|
AUSWMENGE3 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
KATAB4 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART4 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
TQ15
|
QKATAUSW
|
|
AUSWMGWRK4 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
T001W
|
QWERKAUSW
|
|
AUSWMENGE4 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
KATAB5 |
Catalog Entry Is a Selected Set |
CHAR |
1 |
0 |
|
QKTTAB
|
|
KATALGART5 |
Catalog Type of Assigned Code Group or Selected Set |
CHAR |
1 |
0 |
TQ15
|
QKATAUSW
|
|
AUSWMGWRK5 |
Plant of the Assigned Selected Set |
CHAR |
4 |
0 |
T001W
|
QWERKAUSW
|
|
AUSWMENGE5 |
Assigned Code Group or Selected Set |
CHAR |
8 |
0 |
|
QCGRAUSW
|
|
SOLLSTPUMF |
Sample Size to Be Inspected in QM Subsystem |
NUMC |
7 |
0 |
|
QEIFSTUMF
|
|
PROBEMGEH |
Base Unit of Measure for the Inspection Lot |
UNIT |
3 |
0 |
*
|
QEIFMASS
|
|
PROBMGFAK |
Sample Unit of Measurement Factor for QM Subsystem |
NUMC |
6 |
0 |
|
QEIFSTPFAK
|
|
ANNAHMEZ |
Acceptance Number in Attrib. Insp. for QM Subsystems |
NUMC |
5 |
0 |
|
QEIFANNAMZ
|
|
RUECKWEZ |
Rejection Number in Attributive Insp. for QM Subsystems |
NUMC |
5 |
0 |
|
QEIFRUECKZ
|
|
KFAKTOR |
K-Factor for a Variable Inspection |
CHAR |
16 |
0 |
|
QKFAKTORC
|
|
QRKNR |
Control Chart Number |
NUMC |
12 |
0 |
QASH
|
QQRKNR
|
|
PHYSPROBE |
Number of the Partial Sample |
NUMC |
6 |
0 |
*
|
QPHYSPROBE
|
|
KZKORRTRAN |
Correction Transfer Was Carried Out |
CHAR |
1 |
0 |
|
QEIFKORRTR
|
|
ZAEHL |
Internal counter |
NUMC |
8 |
0 |
|
CIM_COUNT
|
|
ANTVERF |
Fraction Calculation |
CHAR |
1 |
0 |
|
QEIFANVERF
|
|
Distribution not specified |
A |
Binomial distribution |
B |
Poisson distribution |
C |
Normal distribution |
|